Defects

Showing 106 defects
Client
All (106)KGF (106)OOFI (0)
Status
Open (106)Resolved (84)All (190)
Property
All (106)GH (30)KH (37)NH (39)OOFI (0)
Severity
All (106)Critical (7)Major (27)Moderate (48)Minor (24)
RefPropertySeverityTitleStatusIdentifiedAction
DEF-2026-0212GHMODERATEFloodlight at back of Gunu House — replacementopen2026-10-22Raise WO
DEF-2026-0207KHMAJORL2 PS Office - Ceiling leakingopen2026-08-25Raise WO
DEF-2026-0206NHMODERATE4ft tube light level 1open2026-08-17Raise WO
DEF-2026-0140KHMAJORSewer waste easementopen2026-08-08Raise WO
DEF-2026-0139KHMAJORNeighbor grey water ingressopen2026-08-08Raise WO
DEF-2026-0137GHMODERATEDPP's office 24000BTU ACopen2026-07-30Raise WO
DEF-2026-0136NHMODERATEL2 Humans Rights Board roomopen2026-07-28Raise WO
DEF-2026-0135NHMODERATEL2 Humans Rights common office spaceopen2026-07-28Raise WO
DEF-2026-0134NHMODERATEL2 Manager Legal's officework ordered2026-07-27Raise WO
DEF-2026-0133NHMODERATEFenceopen2026-07-24Raise WO
DEF-2026-0120NHCRITICALThe Fire Detection/ Alarm System is not functioningopen2026-07-17Raise WO
DEF-2026-0117KHMODERATETube light fixtureopen2026-06-27Raise WO
DEF-2026-0116KHMODERATEMissing windowopen2026-06-27Raise WO
DEF-2026-0113GHMODERATEDPP's office windowopen2026-06-25Raise WO
DEF-2026-0111GHMINORMiddle floor men's washroom sinkopen2026-06-24Raise WO
DEF-2026-0110GHMODERATEMiddle floor lightsopen2026-06-24Raise WO
DEF-2026-0109GHMODERATETop floor kitchen lightsopen2026-06-24Raise WO
DEF-2026-0104KHMAJORWater leakopen2026-05-26Raise WO
DEF-2026-0030KHMODERATEAC drains not connected to downpipeopen2026-02-19Raise WO
DEF-2026-0027KHMAJORWater tank - no non-return valvesopen2026-02-19Raise WO
DEF-2026-0028KHMODERATEInstall shut-off valves for handbasins + sinksopen2026-02-19Raise WO
DEF-2026-0029KHMINORWater meter keys - service or installopen2026-02-19Raise WO
DEF-2026-0031KHMINORV drain covers - installopen2026-02-19Raise WO
DEF-2026-0058NHMAJORL2 Director's room GPOsopen2025-11-26Raise WO
DEF-2026-0055NHMODERATEL2 spare office GPOsopen2025-11-26Raise WO
DEF-2026-0051NHMINORL2 check & test switchesopen2025-11-26Raise WO
DEF-2026-0048NHMODERATEL2 redundant electrical/telecom cablingopen2025-11-26Raise WO
DEF-2026-0047NHMAJORL2 Sub-board test/label/upgradeopen2025-11-26Raise WO
DEF-2026-0054NHMINORL2 GPOs — general check and test required across flooropen2025-11-26Raise WO
DEF-2026-0033NHMAJORMSB inspection #2open2025-11-26Raise WO
DEF-2026-0032NHMAJORMSB inspection #1open2025-11-26Raise WO
DEF-2026-0075NHMODERATEL2 kitchen new IP-rated GPOopen2025-11-26Raise WO
DEF-2026-0069NHCRITICALL2 server room GPOs overloadedopen2025-11-26Raise WO
DEF-2026-0068NHMINORL2 male toilet switchopen2025-11-26Raise WO
DEF-2026-0059NHMODERATEL2 test GPOs & remove redundant cablingopen2025-11-26Raise WO
DEF-2026-0192KHMINORSurface ducting throughoutopen2025-11-07Raise WO
DEF-2026-0125KHCRITICALFire alarm control panel not active — smoke sensors inactiveopen2025-11-07Raise WO
DEF-2026-0126KHCRITICALNo fire hoses or extinguishers on siteopen2025-11-07Raise WO
DEF-2026-0127KHMODERATENo visible fire evacuation plansopen2025-11-07Raise WO
DEF-2026-0128KHMAJORNo backup electrical system installedopen2025-11-07Raise WO
DEF-2026-0129KHMAJOREmergency lighting requires upgradingopen2025-11-07Raise WO
DEF-2026-0130KHMAJORBackup power and water connection not completed at siteopen2025-11-07Raise WO
DEF-2026-0181KHMODERATEOutdoor AC units on ground — vehicle damage riskopen2025-11-07Raise WO
DEF-2026-0182KHMODERATENo emergency muster point signageopen2025-11-07Raise WO
DEF-2026-0183KHMODERATEPedestrian areas blocked — temporary structures and discarded furnitureopen2025-11-07Raise WO
DEF-2026-0184KHMODERATEFence sections require new galvanised meshopen2025-11-07Raise WO
DEF-2026-0185KHMODERATEV-drains and vegetation removal requiredopen2025-11-07Raise WO
DEF-2026-0186KHMINORWall/slab joint cleaning to prevent growthopen2025-11-07Raise WO
DEF-2026-0187KHMODERATERoof gutters likely require cleaningopen2025-11-07Raise WO
DEF-2026-0188KHMAJORNon-compliant AC split-unit pipework penetrationsopen2025-11-07Raise WO
DEF-2026-0189KHCRITICALDetached storage structure blocks fire escapeopen2025-11-07Raise WO
DEF-2026-0190KHMODERATENon fire-rated partitions installedopen2025-11-07Raise WO
DEF-2026-0191KHMAJORNo visible exit or emergency evacuation signageopen2025-11-07Raise WO
DEF-2026-0193KHMODERATENo Disability accessopen2025-11-07Raise WO
DEF-2026-0195KHMAJORIncomplete plumbing works for backup water supplyopen2025-11-07Raise WO
DEF-2026-0198KHMODERATEDownpipes, fixings, V-drains and downpipe drains — cleaningopen2025-11-07Raise WO
DEF-2026-0199KHMODERATEEstablish AC servicing and testing regimeopen2025-11-07Raise WO
DEF-2026-0200KHMODERATECompliant HVAC penetrations required on AC changeoutsopen2025-11-07Raise WO
DEF-2026-0201KHMINORRemove redundant AC unitsopen2025-11-07Raise WO
DEF-2026-0202KHMAJORMSB and sub-boards — RCD/load testing requiredopen2025-11-07Raise WO
DEF-2026-0203KHMINOROld fluorescent tube lighting — upgrade opportunityopen2025-11-07Raise WO
DEF-2026-0161GHMAJORDriveway pavement damage — FRA responsibilityopen2025-11-04Raise WO
DEF-2026-0162GHMODERATEBackup water supply — sub-standard installationopen2025-11-04Raise WO
DEF-2026-0163GHMINORLandscaping — minor drain cleaning and clearingopen2025-11-04Raise WO
DEF-2026-0164GHMAJORRecurring sewer manhole overflow during heavy rainopen2025-11-04Raise WO
DEF-2026-0165GHMODERATERoof gutters likely require cleaningopen2025-11-04Raise WO
DEF-2026-0166GHMINORExternal surfaces — rust stains and mould cleaningopen2025-11-04Raise WO
DEF-2026-0167GHMODERATERotting external timber cladding at lobby/waiting areaopen2025-11-04Raise WO
DEF-2026-0168GHMINORBlanking plate for old access control penetrationopen2025-11-04Raise WO
DEF-2026-0169GHMINORTimber stairs — sand and re-glaze refurbishmentopen2025-11-04Raise WO
DEF-2026-0170GHMODERATENon-slip strips on stair treads (tenant request)open2025-11-04Raise WO
DEF-2026-0171GHMINORWater supply pressure testing recommendedopen2025-11-04Raise WO
DEF-2026-0172GHMAJORSewer line overflow at entryopen2025-11-04Raise WO
DEF-2026-0173GHMODERATEEstablish AC servicing and testing regimeopen2025-11-04Raise WO
DEF-2026-0174GHMINORRemove redundant AC unitsopen2025-11-04Raise WO
DEF-2026-0175GHMODERATEHVAC testing/balancing/controls in PM regimeopen2025-11-04Raise WO
DEF-2026-0176GHMINORChimneys and vents follow-up auditopen2025-11-04Raise WO
DEF-2026-0177GHMAJORMSB and sub-boards — RCD/load testing requiredopen2025-11-04Raise WO
DEF-2026-0178GHMAJORGround-floor tea room GPO constantly trippingopen2025-11-04Raise WO
DEF-2026-0179GHMODERATEIP65 GPO required for hot water unit in staff bathroomopen2025-11-04Raise WO
DEF-2026-0180GHMINOROld fluorescent/CFL lighting — upgrade opportunityopen2025-11-04Raise WO
DEF-2026-0123GHMINORFire evacuation plan drawings fadedopen2025-11-04Raise WO
DEF-2026-0122GHMODERATEFire extinguishers and hoses require servicing auditopen2025-11-04Raise WO
DEF-2026-0121GHCRITICALFire alarm control panel not activeopen2025-11-04Raise WO
DEF-2026-0204NHMAJORBackup generator not installed — per tenancy agreementopen2025-11-04Raise WO
DEF-2026-0205NHMAJORBackup water supply connection/installation not completedopen2025-11-04Raise WO
DEF-2026-0124GHMODERATEBackup generator follow-up audit requiredopen2025-11-04Raise WO
DEF-2026-0141NHMAJORDriveway chamber cover requires replacementopen2025-11-04Raise WO
DEF-2026-0142NHMODERATENo emergency muster point signageopen2025-11-04Raise WO
DEF-2026-0143NHMODERATEPedestrian access blocked — discarded material on siteopen2025-11-04Raise WO
DEF-2026-0144NHMINORWall/slab joint cleaning to prevent growthopen2025-11-04Raise WO
DEF-2026-0146NHMODERATEMain roof gutters require cleaningopen2025-11-04Raise WO
DEF-2026-0147NHMINORConcrete window sills require cleaningopen2025-11-04Raise WO
DEF-2026-0148NHMINORInterior finishes tired — wet area tiles and ceilingsopen2025-11-04Raise WO
DEF-2026-0149NHMINORKitchenette cabinets need updating and expansionopen2025-11-04Raise WO
DEF-2026-0150NHMAJORNo visible exit signs or emergency evacuation signageopen2025-11-04Raise WO
DEF-2026-0145NHCRITICALElevator — shaft, well and full conveyance inspection requiredopen2025-11-04Raise WO
DEF-2026-0152NHMODERATEAdditional sanitary facilities with Disability accessopen2025-11-04Raise WO
DEF-2026-0153NHMINORNo sanitary bins or sanitary services provider engagedopen2025-11-04Raise WO
DEF-2026-0154NHMODERATEStormwater drains require checking and clearingopen2025-11-04Raise WO
DEF-2026-0155NHMODERATEEstablish AC servicing and testing regimeopen2025-11-04Raise WO
DEF-2026-0156NHMODERATECompliant HVAC penetrations requiredopen2025-11-04Raise WO
DEF-2026-0157NHMAJORFire alarm control panel not installed — manual call points onlyopen2025-11-04Raise WO
DEF-2026-0158NHMODERATENo visible fire evacuation route plansopen2025-11-04Raise WO
DEF-2026-0159NHMAJORElectrical and telecom closets — rubbish/cleaning items stored — OHS/fire riskopen2025-11-04Raise WO
DEF-2026-0160NHMODERATELightning protection requires licensed electrical inspectionopen2025-11-04Raise WO